{"id":4115,"date":"2023-05-23T11:16:18","date_gmt":"2023-05-23T10:16:18","guid":{"rendered":"https:\/\/www.bcta.group\/attma\/?page_id=4115"},"modified":"2023-05-23T11:19:16","modified_gmt":"2023-05-23T10:19:16","slug":"attma-anz-air-testing-equipment-and-calibration","status":"publish","type":"page","link":"https:\/\/www.bcta.group\/attma\/attma-anz-air-testing-equipment-and-calibration\/","title":{"rendered":"ATTMA ANZ Air Testing Equipment and Calibration"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"4115\" class=\"elementor elementor-4115\" data-elementor-settings=\"{&quot;ha_cmc_init_switcher&quot;:&quot;no&quot;}\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f368dd5 e-flex e-con-boxed e-con e-parent\" data-id=\"f368dd5\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-94e86af elementor-widget elementor-widget-heading\" data-id=\"94e86af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ATTMA ANZ Air Tightness Testing Equipment and Calibration<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-030f282 e-flex e-con-boxed e-con e-parent\" data-id=\"030f282\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-66d8526 elementor-widget elementor-widget-text-editor\" data-id=\"66d8526\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Equipment<\/strong><\/p><p>Testers must be familiar with and competent in the operation of any and all testing equipment they use to carry out air tightness tests in accordance with industry standards called for in Building Regulations, Parts L1 and L2, whether owned, borrowed or hired.<\/p><p>A record should be kept of all equipment used for testing and pre-completion testing including that which is not owned by the tester. Details of equipment used but not owned by the tester should be included in the information submitted for the next annual audit.<\/p><p>Scheme members should have procedures in place to ensure that borrowed or hired equipment is a) in calibration and b) performing correctly. Calibration certificates for the borrowed or hired equipment must be presented at the next annual audit.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-143ea04 e-flex e-con-boxed e-con e-parent\" data-id=\"143ea04\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9e32622 elementor-widget elementor-widget-text-editor\" data-id=\"9e32622\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Calibration<\/strong><\/p><p>All the following specification are required of all equipment used, which must all be undertaken by a UKAS\/iLAC accredited calibration laboratory.<\/p><p>Fans &#8211; 5 year calibration<br \/>Manometer &#8211; 2 year calibration<br \/>Thermometer &#8211; 2 year calibration<\/p><p>Pressure differential measurement devices (Micro-manometer) must be capable of measuring pressure differentials with an accuracy of \u00b12 Pascals in the range of 0 to \u00b1100 Pascals.<\/p><p>Air flow rate measurement devices must have a flow measurement accuracy not greater than 7% of the reading.<\/p><p>Where multiple fans and measurement systems are to be used in unison then the calibration of all individual units needs to be verified.<\/p><p>Temperature measurement devices must have an accuracy of \u00b11\u00b0C within the range of -20\u00b0C to +40\u00b0C.<\/p><p>Barometric pressure measurement devices must have an accuracy of \u00b15 mbar in the range of 950 \u2013 1050 mbar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>ATTMA ANZ Air Tightness Testing Equipment and Calibration Equipment Testers must be familiar with and competent in the operation of<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-4115","page","type-page","status-publish","hentry"],"publishpress_future_action":{"enabled":false,"date":"2026-06-02 03:17:26","action":"change-status","newStatus":"draft","terms":[],"taxonomy":"","extraData":[]},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.bcta.group\/attma\/wp-json\/wp\/v2\/pages\/4115","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bcta.group\/attma\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.bcta.group\/attma\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.bcta.group\/attma\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bcta.group\/attma\/wp-json\/wp\/v2\/comments?post=4115"}],"version-history":[{"count":3,"href":"https:\/\/www.bcta.group\/attma\/wp-json\/wp\/v2\/pages\/4115\/revisions"}],"predecessor-version":[{"id":4118,"href":"https:\/\/www.bcta.group\/attma\/wp-json\/wp\/v2\/pages\/4115\/revisions\/4118"}],"wp:attachment":[{"href":"https:\/\/www.bcta.group\/attma\/wp-json\/wp\/v2\/media?parent=4115"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}