{"id":812,"date":"2021-04-21T14:39:45","date_gmt":"2021-04-21T14:39:45","guid":{"rendered":"https:\/\/www.bcta.group\/dbma\/?page_id=812"},"modified":"2021-10-27T14:15:18","modified_gmt":"2021-10-27T14:15:18","slug":"vendor-verification-exercise-floor-regularity","status":"publish","type":"page","link":"https:\/\/www.bcta.group\/dbma\/vendor-verification-exercise-floor-regularity\/","title":{"rendered":"Vendor Verification Exercise &#8211; Floor Regularity"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Vendor Verification Exercise &#8211; Floor Regularity &#8211; Laser Scanning<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The following companies and individuals were assessed at The Building Performance Hub using the &#8216;Landing Strip&#8217; floor section to assess their competence to measure an area of floor using scanners. The vendors measured and reported on an area of floor approximately 37.5m2 which was verified against a high end laser scanner. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This list shows the vendors that carried out that process. It does not indicate that vendors are certified or authorised by the DBMA in any way. <\/p>\n\n\n\n<table id=\"tablepress-7\" class=\"tablepress tablepress-id-7\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\"><b>Company Name<\/th><th class=\"column-2\"><b>Surveyor<\/th><th class=\"column-3\"><b>Equipment &amp; Max Scan Distance<\/th><th class=\"column-4\"><b>Approval Expiry Date<\/th><th class=\"column-5\"><b>Status<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Buckler\/ Synderford Ltd<\/td><td class=\"column-2\">Richard Buckler<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Excelsa Floors<\/td><td class=\"column-2\">John Hindley<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Excelsa Floors<\/td><td class=\"column-2\">Macauley Hill<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Face Consultants<\/td><td class=\"column-2\">Eduardo Aguinaga<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Face Consultants<\/td><td class=\"column-2\">Jamie Fawcett<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Face Consultants<\/td><td class=\"column-2\">Carter Wilson<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Face Consultants<\/td><td class=\"column-2\">Richard Dirige<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Geo-Precise<\/td><td class=\"column-2\">Andras Bodoczi<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Geo-Precise<\/td><td class=\"column-2\">Bence Pintye<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">M\u00fcller &amp; Lobisch <\/td><td class=\"column-2\">Martin Tiessen<\/td><td class=\"column-3\">Faro Focus S70 <br>Scan distances maximum 7m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Plowman Craven<\/td><td class=\"column-2\">Alberto Benatti<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Plowman Craven<\/td><td class=\"column-2\">Davide Bisi<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Plowman Craven<\/td><td class=\"column-2\">Jonathan Fletcher<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Plowman Craven<\/td><td class=\"column-2\">Piotr Trzyna<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">PL28 \/ ACRE<\/td><td class=\"column-2\">Oscar Gonzalez D\u00edaz<\/td><td class=\"column-3\">Leica ScanStation P40 <br>Scan distances maximum 10m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Qualidal<\/td><td class=\"column-2\">Bastien Couenne<\/td><td class=\"column-3\">Faro Focus S70 <br>Scan distances maximum 7m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Qualidal<\/td><td class=\"column-2\">Joshua Petit<\/td><td class=\"column-3\">Faro Focus S70 <br>Scan distances maximum 7m<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-7 from cache -->\n\n\n\n<hr class=\"wp-block-separator\"\/>\n\n\n<h2>Vendor Verification Exercise &#8211; Floor Regularity &#8211; Mechanical Measurements<\/h2>\n<p>The following companies and individuals were assessed at The Building Performance Hub using the &#8216;Landing Strip&#8217; floor section to assess their competence to measure an area of floor using mechanical equipment. The vendors measured and reported on an area of floor approximately 37.5m2 which was verified against a high end laser scanner.<\/p>\n<p><!-- \/wp:post-content --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>This list shows the vendors that carried out that process. It does not indicate that vendors are certified or authorised by the DBMA in any way.<!-- \/wp:paragraph --><\/p>\n<p><!-- \/wp:paragraph --><\/p>\n<p><!-- wp:shortcode --><br \/>\n<table id=\"tablepress-8\" class=\"tablepress tablepress-id-8\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\"><b>Company Name<\/th><th class=\"column-2\"><b>Surveyor<\/th><th class=\"column-3\">Equipment<\/th><th class=\"column-4\"><b>Approval Expiry Date<\/th><th class=\"column-5\"><b>Status<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Face Consultants<\/td><td class=\"column-2\">Eduardo Aguinaga<\/td><td class=\"column-3\">Profileograph<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Face Consultants<\/td><td class=\"column-2\">Dominic Bayliss<\/td><td class=\"column-3\">Profileograph<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Face Consultants<\/td><td class=\"column-2\">Sean Creamer<\/td><td class=\"column-3\">Profileograph<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Face Consultants<\/td><td class=\"column-2\">Michael Heyward<\/td><td class=\"column-3\">Profileograph<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Face Consultants<\/td><td class=\"column-2\">Jordan Mitchell<\/td><td class=\"column-3\">Profileograph<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Face Consultants<\/td><td class=\"column-2\">Valdmir Santo<\/td><td class=\"column-3\">Profileograph<\/td><td class=\"column-4\">1 April 2024<\/td><td class=\"column-5\">Requirements Met<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-8 from cache --><br \/><!-- \/wp:shortcode --><\/p>\n\n<!-- wp:separator -->\n<hr class=\"wp-block-separator\"\/>\n<!-- \/wp:separator -->","protected":false},"excerpt":{"rendered":"<p>Vendor Verification Exercise &#8211; Floor Regularity &#8211; Laser Scanning The following companies and individuals were assessed at The Building Performance<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-builder.php","meta":{"colormag_page_container_layout":"default_layout","colormag_page_sidebar_layout":"default_layout","footnotes":""},"class_list":["post-812","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>DBMA | Vendor Verification Exercise - Floor Regularity<\/title>\n<meta name=\"robots\" content=\"noindex, nofollow\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DBMA | Vendor Verification Exercise - Floor Regularity\" \/>\n<meta property=\"og:description\" content=\"Vendor Verification Exercise &#8211; Floor Regularity &#8211; Laser Scanning The following companies and individuals were assessed at The Building Performance\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bcta.group\/dbma\/vendor-verification-exercise-floor-regularity\/\" \/>\n<meta property=\"og:site_name\" content=\"DBMA\" \/>\n<meta property=\"article:modified_time\" content=\"2021-10-27T14:15:18+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/vendor-verification-exercise-floor-regularity\\\/\",\"url\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/vendor-verification-exercise-floor-regularity\\\/\",\"name\":\"DBMA | Vendor Verification Exercise - Floor Regularity\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/#website\"},\"datePublished\":\"2021-04-21T14:39:45+00:00\",\"dateModified\":\"2021-10-27T14:15:18+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/vendor-verification-exercise-floor-regularity\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/vendor-verification-exercise-floor-regularity\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/vendor-verification-exercise-floor-regularity\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Vendor Verification Exercise &#8211; Floor Regularity\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/#website\",\"url\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/\",\"name\":\"DBMA\",\"description\":\"Digital Building Measurement Association\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/#organization\",\"name\":\"DBMA\",\"url\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"\",\"contentUrl\":\"\",\"caption\":\"DBMA\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bcta.group\\\/dbma\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"DBMA | Vendor Verification Exercise - Floor Regularity","robots":{"index":"noindex","follow":"nofollow"},"og_locale":"en_GB","og_type":"article","og_title":"DBMA | Vendor Verification Exercise - Floor Regularity","og_description":"Vendor Verification Exercise &#8211; Floor Regularity &#8211; Laser Scanning The following companies and individuals were assessed at The Building Performance","og_url":"https:\/\/www.bcta.group\/dbma\/vendor-verification-exercise-floor-regularity\/","og_site_name":"DBMA","article_modified_time":"2021-10-27T14:15:18+00:00","twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.bcta.group\/dbma\/vendor-verification-exercise-floor-regularity\/","url":"https:\/\/www.bcta.group\/dbma\/vendor-verification-exercise-floor-regularity\/","name":"DBMA | Vendor Verification Exercise - Floor Regularity","isPartOf":{"@id":"https:\/\/www.bcta.group\/dbma\/#website"},"datePublished":"2021-04-21T14:39:45+00:00","dateModified":"2021-10-27T14:15:18+00:00","breadcrumb":{"@id":"https:\/\/www.bcta.group\/dbma\/vendor-verification-exercise-floor-regularity\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bcta.group\/dbma\/vendor-verification-exercise-floor-regularity\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.bcta.group\/dbma\/vendor-verification-exercise-floor-regularity\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.bcta.group\/dbma\/"},{"@type":"ListItem","position":2,"name":"Vendor Verification Exercise &#8211; Floor Regularity"}]},{"@type":"WebSite","@id":"https:\/\/www.bcta.group\/dbma\/#website","url":"https:\/\/www.bcta.group\/dbma\/","name":"DBMA","description":"Digital Building Measurement Association","publisher":{"@id":"https:\/\/www.bcta.group\/dbma\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bcta.group\/dbma\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.bcta.group\/dbma\/#organization","name":"DBMA","url":"https:\/\/www.bcta.group\/dbma\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.bcta.group\/dbma\/#\/schema\/logo\/image\/","url":"","contentUrl":"","caption":"DBMA"},"image":{"@id":"https:\/\/www.bcta.group\/dbma\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.bcta.group\/dbma\/wp-json\/wp\/v2\/pages\/812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bcta.group\/dbma\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.bcta.group\/dbma\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.bcta.group\/dbma\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bcta.group\/dbma\/wp-json\/wp\/v2\/comments?post=812"}],"version-history":[{"count":6,"href":"https:\/\/www.bcta.group\/dbma\/wp-json\/wp\/v2\/pages\/812\/revisions"}],"predecessor-version":[{"id":859,"href":"https:\/\/www.bcta.group\/dbma\/wp-json\/wp\/v2\/pages\/812\/revisions\/859"}],"wp:attachment":[{"href":"https:\/\/www.bcta.group\/dbma\/wp-json\/wp\/v2\/media?parent=812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}